Kidde Battery Powered Combination Smoke & Carbon Monoxide alarm with Voice Alerts
900-CUDR-VCA
Features
-
2-in-1 Detection - Combination detector alerts you to both smoke and carbon monoxide (CO) in a single device
-
120V AC hardwired with AA backup batteries - Provides reliable detection, even during power outages. Easy install mounting bracket (included) for quick installation in 4 orientations
-
Voice alarm announces hazard type: fire, carbon monoxide gas and sounds an 85-decibel alarm. CUL/CSA Certified with a 10-year limited warranty
-
Photoelectric smoke sensor may detect visible fire particles associated with slow, smoldering fires faster than ionizing alarms
-
Self-Testing - Uses internal, self-testing components to ensure the device is operating as expected (not a substitute for weekly manual testing)
-
LED warning indicators alert you to various status: green = normal operation, amber = operating error, and red = smoke, fire or carbon monoxide event
The Kidde Battery Powered Combination Smoke & Carbon Monoxide Alarm with Voice Alerts, model 900-CUDR-VCA, uses 2 AA alkaline batteries to power the unit. Photoelectric sensor technology may detect visible fire particles associated with slow, smoldering fires faster than ionization alarms. The voice alarm announces hazard type: “Fire!” when a smoke hazard is detected, “Warning Carbon Monoxide” when CO is detected, or “Low Battery” when batteries need to be replaced. The LED light indicator shows alarm status. The Test-Hush button activates the temporary silence of nuisance alarms, test the unit’s electronics, silences a low battery or end-of-life chirp for up to 24 hours at a time for a maximum of 7 days and resets the device after a CO incident.
Please click on this link to see videoKey Features
-
2-in-1 Detection - Combination detector alerts you to both smoke and carbon monoxide (CO) in a single device
-
2 AA alkaline batteries power the detector. Easy install mounting bracket (included) for quick installation in 4 orientations
-
Voice alarm announces hazard type: fire, carbon monoxide gas and sounds an 85-decibel alarm. CUL/CSA Certified with a 10-year limited warranty
-
Photoelectric smoke sensor may detect visible fire particles associated with slow, smoldering fires faster than ionizing alarms
-
Self-Testing - Uses internal, self-testing components to ensure the device is operating as expected (not a substitute for weekly manual testing)
-
LED warning indicators alert you to various status: green = normal operation, amber = operating error, and red = smoke, fire or carbon monoxide event
Technical Specifications
Model: | 900-CUDR-VCA |
Power Source: | 2 AA batteries |
Smoke Sensor: | Photoelectric |
CO Sensor: | Electrochemical |
Audio Alarm: | 85dB at 3 meters |
Temperature Range: | 4.4˚C (40˚F) to 37.8˚C (100˚F) |
Humidity Range: | 10%-95% relative humidity, non-condensing |
Size: | 12.6 cm in diameter x 4.9 cm depth |
Weight: | 0.24 kg |
Interconnects: | No |
Warranty: | 10-year limited (batteries excluded) |
Replacement batteries: | Energizer E91, Gold Peak 15A, Golden Power GLR6A. Replacement batteries are available where you purchased this alarm.
Note: Do not use lithium batteries in this unit. |
The Kidde Battery Powered Combination Smoke & Carbon Monoxide Alarm with Voice Alerts, model 900-CUDR-VCA, uses 2 AA alkaline batteries to power the unit. Photoelectric sensor technology may detect visible fire particles associated with slow, smoldering fires faster than ionization alarms. The voice alarm announces hazard type: “Fire!” when a smoke hazard is detected, “Warning Carbon Monoxide” when CO is detected, or “Low Battery” when batteries need to be replaced. The LED light indicator shows alarm status. The Test-Hush button activates the temporary silence of nuisance alarms, test the unit’s electronics, silences a low battery or end-of-life chirp for up to 24 hours at a time for a maximum of 7 days and resets the device after a CO incident.
Please click on this link to see videoKey Features
-
2-in-1 Detection - Combination detector alerts you to both smoke and carbon monoxide (CO) in a single device
-
2 AA alkaline batteries power the detector. Easy install mounting bracket (included) for quick installation in 4 orientations
-
Voice alarm announces hazard type: fire, carbon monoxide gas and sounds an 85-decibel alarm. CUL/CSA Certified with a 10-year limited warranty
-
Photoelectric smoke sensor may detect visible fire particles associated with slow, smoldering fires faster than ionizing alarms
-
Self-Testing - Uses internal, self-testing components to ensure the device is operating as expected (not a substitute for weekly manual testing)
-
LED warning indicators alert you to various status: green = normal operation, amber = operating error, and red = smoke, fire or carbon monoxide event
Technical Specifications
Model: | 900-CUDR-VCA |
Power Source: | 2 AA batteries |
Smoke Sensor: | Photoelectric |
CO Sensor: | Electrochemical |
Audio Alarm: | 85dB at 3 meters |
Temperature Range: | 4.4˚C (40˚F) to 37.8˚C (100˚F) |
Humidity Range: | 10%-95% relative humidity, non-condensing |
Size: | 12.6 cm in diameter x 4.9 cm depth |
Weight: | 0.24 kg |
Interconnects: | No |
Warranty: | 10-year limited (batteries excluded) |
Replacement batteries: | Energizer E91, Gold Peak 15A, Golden Power GLR6A. Replacement batteries are available where you purchased this alarm.
Note: Do not use lithium batteries in this unit. |